1. General description:
Broadly applied to running of single-phase AC motors at 0Hz(60Hz)frequency for washers and high efficiency compressors of refrigerators etc.
2. features:
The capacitor takes heavy-edge metallized, AI/Zn pp film or web-like fuse metallized PP film as dielectric, its components are assembled in flame-retardant ABS or PBT cylindrical crust, impregnated with flame-retardant epoxy resin, It has high reliability and
stability.
3.Technical parameter
Standard:GB3667-1997,same as IEC60252:193
Climate type:40/70/21, 40/85/21
Capacitance tolerance: ±5%
Dielectric dissipation factor: tg&≤0.002(50Hz~100Hz)
Life expectancy:3000h(Class C)or10000h(Class B)
4.Service condition
Altitude:≤2000m
Residual voltage in application:Less than 10% of rated voltage
Allowed maximum voltage: Less than 1.1 times of rated voltage
Permissible maximum current: Less than 1.3 times of rated current
Outline size
Product Photo:

Application

Factory photos:


Certification:


Broadly applied to running of single-phase AC motors at 0Hz(60Hz)frequency for washers and high efficiency compressors of refrigerators etc.
2. features:
The capacitor takes heavy-edge metallized, AI/Zn pp film or web-like fuse metallized PP film as dielectric, its components are assembled in flame-retardant ABS or PBT cylindrical crust, impregnated with flame-retardant epoxy resin, It has high reliability and
stability.
3.Technical parameter
Standard:GB3667-1997,same as IEC60252:193
Climate type:40/70/21, 40/85/21
Capacitance tolerance: ±5%
Dielectric dissipation factor: tg&≤0.002(50Hz~100Hz)
Life expectancy:3000h(Class C)or10000h(Class B)
Capacitance range | 1-120μf |
Rated voltage Un | 250v.ac/400/450V.ac |
Rated frequency | 50Hz;60Hz |
Capacitance tolerance | ±5%;±10% |
Climatic category | -25+70°C |
Dissipation factor(at 50Hz-Hz and 20°C) | ≤0.002(100Hz,20°C) |
Test voltage between terminals | 2×Un for 3s |
Test voltage between terminals and case | 2×Un+1000VDC FOR 2s |
Reference standard | EN 60252-1:2001;IEC252 |
4.Service condition
Altitude:≤2000m
Residual voltage in application:Less than 10% of rated voltage
Allowed maximum voltage: Less than 1.1 times of rated voltage
Permissible maximum current: Less than 1.3 times of rated current
Outline size
1.0UF/450VAC | 30*57 |
1.5UF/450VAC | 30*57 |
2.5UF/450VAC | 30*57 |
3.0UF/450VAC | 30*57 |
3.5UF/450VAC | 30*57 |
4.5UF/450VAC | 30*57 |
6.0UF/450VAC | 30*57 |
6.3UF/450VAC | 35*66 |
8.0UF/450VAC | 35*66 |
10.0UF/450VAC | 35*66 |
12UF/450VAC | 40*71 |
14UF/450VAC | 40*71 |
16UF/450VAC | 40*71 |
18UF/450VAC | 40*71 |
20UF/450VAC | 40*95 |
25UF/450VAC | 40*95 |
30UF/450VAC | 45*95 |
40UF/450VAC | 50*107 |
50UF/450VAC | 50*107 |
60UF/450VAC | 50*117 |
2UF/450V+CABLE | 30*59 |
4UF/450V + CABLE | 30*59 |
8UF/450V+CABLE | 35*69 |
10UF/450V+CABLE | 35*69 |
12UF/450V+CABLE | 40*73 |
16UF/450V+CABLE | 40*73 |
20UF/450v+cable | 40*98 |
25UF/450V+CABLE | 40*98 |
30UF/450V+CABLE | 45*98 |
40UF/450V+CABLE | 50*109 |
50UF/450V+CABLE | 50*109 |
60UF/450V+CABLE | 50*119 |
Product Photo:

Application

Factory photos:


Certification:

